Second generation of intrauterine balloon tamponade: new perspective ==================================================================== * Younes Bakri * Christopher B-Lynch * Souhail Alouini * inventions * delivery * obstetrics ## Commentary Every day in the year 2015, about 830 women died of childbirth and pregnancy complications. Almost all these deaths occurred in low resource settings, and most could have been prevented. The primary causes of death were *haemorrhage, hypertension and sepsis*.1 The last two decades witnessed global efforts, including Public Health, clinical, academic, administrative and socioeconomic, to save lives at birth, worldwide. In low-income and middle-income countries, the risk of a woman dying of a maternal-related cause during her lifetime is about 33 times higher, compared with a woman living in a developed country. The number of women dying of complications during pregnancy and childbirth has decreased by 43%, from an estimated 532 000 deaths in the year 1990, down to 303 000 deaths in the year 2015, a testimonial that Global collaborative efforts ‘work’.1 Progress was achieved in the management of maternal postpartum haemorrhage (PPH) of vaginal birth and Caesarean section2–7; however, less progress was attained in case of pregnancy-related bacterial sepsis, including puerperal sepsis and postabortion sepsis, particularly unsafe abortion’s intrauterine infection. Sepsis is one of the leading causes of maternal mortality, worldwide. Introduced in the year 1999, *Bakri SOS Tamponade Balloon*,4 8–10 was the first uterine tamponade balloon system for the treatment of PPH.4 9 11 Multiple other devices followed, including: condom catheters,12 BT-Cath,13 ESM-UBT (Every Second Matters - Uterine Balloon Tamponade),14 Ebb balloon15 and Zhukovsky balloon.16 Successful outcome (haemorrhage control) without the need for additional treatments such as embolisation,2 B-lynch compression,4 B-LUVS sutures and multiple square sutures,4 17 uterine-hypogastric artery ligation, hysterectomy were reported. All other treatments except embolisation,2 required an open laparotomy surgery to control PPH. Tamponade devices’ complications of migration/expulsion, rupture/leakage, uterus perforation and infection were reported. Pregnancy-related haemorrhage and sepsis (including unsafe abortion and molar pregnancy), are the leading causes of maternal death in the low-resources regions worldwide. A recent WHO 2016 report estimated that during the time period of 2010–2014, there were 35 abortions per 1000 women (aged 15–44) worldwide. This translates to over 56 million abortions per year. An earlier WHO 2008 report the following estimates that 21.6 million women experience ‘unsafe abortion’ worldwide each year and most of them occurred in low-income and middle-income countries. Death due to ‘unsafe abortion’ remains close to 13% of all maternal deaths. Types of currently available tamponade devices. The following balloon catheters were designed for placement in the uterus for tamponade control of PPH, occurring after vaginal or Caesarean section birth4: * Bakri tamponade balloon catheter—the Bakri tamponade balloon catheter is the first uterine tamponade balloon system designed specifically for the treatment of obstetric haemorrhage.4 It consists of a silicone balloon (maximum recommended fill volume 500 mL), connected to a 24 French silicone catheter 54 cm in length. The collapsed balloon is inserted into the uterus when filled with fluid, the balloon adapts to the configuration of the uterine cavity to tamponade uterine bleeding. The central lumen of the catheter allows drainage and is designed to monitor ongoing bleeding above the level of the balloon. The device is intended for one-time use. * BT-Cath—the BT-Cath4 is a silicone balloon (maximum recommended fill volume 500 mL) with an inverted pear shape to conform to the shape of the uterine cavity. In contrast to the Bakri tamponade balloon catheter, BT-Cath’s end of the catheter is flush with the end of the balloon. One lumen of the dual lumen catheter is used to infuse saline and expand the balloon, while the other lumen allows drainage of blood from the fundus. It is intended for one-time use. * ebb tamponade system4—The ebb tamponade system is a dual polyurethane balloon device containing an upper uterine balloon (maximum recommended fill volume 750 mL) and a lower vaginal balloon (maximum recommended fill volume 300 mL). A central drain allows for monitoring of possible ongoing or recurrent haemorrhage from above the uterine balloon. The device is intended for one-time use. Other devices that have been used for uterine tamponade, but are not intended for this purpose, include the following: * Sengstaken-Blakemore tube (used for treatment of bleeding oesophageal varices). * Single or multiple Foley catheters (used for bladder drainage). * Rusch urological balloon (used for stretching the bladder). * Condom catheter (a condom is placed over the end of a Foley-type catheter, the base of the condom is ligated to the catheter to prevent leakage and then the condom is filled with up to 500 mL fluid via the catheter). * Size 8 surgical glove tied to an intravenous infusion or other catheter, and then filled with up to 500 mL fluid. Rusch balloons, surgical glove and condom catheters are made of latex rubber; the other devices are made of silicone or polyurethane. ## Intrauterine balloon: second generation *BakriOne balloon* is a new second generation tamponade balloon design system, for the treatment of pregnancy-related uterine haemorrhage and infection, is a novel technology design system which takes into consideration all possible variations in the clinical presentation of pregnancy-related uterine haemorrhage and/or sepsis. It brings a bold, off the beaten path treatment approach, applicable to all pregnancy trimesters and covers normal or abnormal pregnancies including, abortion, miscarriage and hydatidiform mole pregnancies. Trademark Application for: ‘BakriOne.’ US Trademark Application No: 87937508. Our Matter Docket No: 00510.003-TM-USW (BakriOne). Status: allowed. The *BakriOne* is a multisize, multimaterial, multiport and multifunction system. A variety of tube-catheter sizes from 24 Fr. to 48 Fr. Meets patient tube sizing needs. A variety of balloon component sizes from 50cc to 750cc Meets patient balloon sizing needs including abortion, pregnancy trimesters, twins, hydatidiform mole. The clear silicone or polyvinyl chloride (PVC) shaft, allows for better visualisation of flow and helps in care and maintenance. Separate medication port for intrauterine topical treatments, for example, uterotonics, antibiotics, tranexamic acid as the efficiency of these treatment were reported in other studies.18–20 Radiopaque stripe for X-ray placement verification. Drainage obstruction will be easy to identify with the translucent silicone or PVC tubing. The PVC ‘Carus-Curve’ (size 48 Fr. tubing option), conforms to the anatomy of the birth canal and helps preventing expulsion of the balloon, a problem which occurs in about 10% of currently available balloons. The *BakriOne* balloon is hereby proposed to treat the pregnancy-related haemorrhage and intrauterine infections/complications as deemed appropriate. Functions of the BakriOne are included in table 1. View this table: [Table 1](http://innovations.bmj.com/content/6/1/1/T1) Table 1 Functions of the BakriOne The versatility of the *BakriOne* system’s technology extends its benefits and applications to all global geographic regions, including, the lower resources regions. It is designed as a safe, simple, cost-effective and easy-to-use technology. User-friendly—does not require assembly. Readily available to apply in emergency situations, even in remote rural locations. ## Footnotes * Contributors YB designed the device, wrote and approved the article; CB-L participated to the content and approved the article; SA designed, particpated to the content, wrote and approved the article. * Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors. * Competing interests None declared * Patient consent for publication Not required. * Provenance and peer review Not commissioned; externally peer reviewed. [http://creativecommons.org/licenses/by-nc/4.0/](http://creativecommons.org/licenses/by-nc/4.0/) This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: [http://creativecommons.org/licenses/by-nc/4.0/](http://creativecommons.org/licenses/by-nc/4.0/). ## References 1. WHO, UNICEF, UNFPA, World Bank Group and the United Nations Population Division. Trends in maternal mortality: 1990 to 2015: estimates by who, UNICEF, UNFPA, world bank group and the United nations population division, 2016. Available: [https://www.who.int/reproductivehealth/publications/monitoring/maternal-mortality-2015/en/](https://www.who.int/reproductivehealth/publications/monitoring/maternal-mortality-2015/en/) 2. Bakri YN , Linjawi T . Angiographic embolization for control of pelvic genital tract hemorrhage. Report of 14 cases. Acta Obstet Gynecol Scand 1992;71:17–21.[doi:10.3109/00016349209007941](http://dx.doi.org/10.3109/00016349209007941) [CrossRef](http://innovations.bmj.com/lookup/external-ref?access_num=10.3109/00016349209007941&link_type=DOI) [PubMed](http://innovations.bmj.com/lookup/external-ref?access_num=1315091&link_type=MED&atom=%2Fbmjinnov%2F6%2F1%2F1.atom) 3. Doumouchtsis SK , Papageorghiou AT , Arulkumaran S . Systematic review of conservative management of postpartum hemorrhage: what to do when medical treatment fails. Obstet Gynecol Surv 2007;62:540–7.[doi:10.1097/01.ogx.0000271137.81361.93](http://dx.doi.org/10.1097/01.ogx.0000271137.81361.93) [CrossRef](http://innovations.bmj.com/lookup/external-ref?access_num=10.1097/01.ogx.0000271137.81361.93&link_type=DOI) [PubMed](http://innovations.bmj.com/lookup/external-ref?access_num=17634155&link_type=MED&atom=%2Fbmjinnov%2F6%2F1%2F1.atom) [Web of Science](http://innovations.bmj.com/lookup/external-ref?access_num=000248349000003&link_type=ISI) 4. Bakri Y , Arulkumaran S . Intrauterine balloon tamponade for control of postpartum hemorrhage, UpToDate, 2017. Available: [https://www.uptodate.com/contents/intrauterine-balloon-tamponade-for-control-of-postpartum-hemorrhage](https://www.uptodate.com/contents/intrauterine-balloon-tamponade-for-control-of-postpartum-hemorrhage) 5. Ramsbotham PH . The principles and practice of obstetrical medicine and surgery. 371. Philadelphia, PA, USA: Blanchard and Lea, 1856: 415–6. 6. Douglass LH . The passing of the pack. Bull Sch Med Univ Md 1955;40:37–9. 7. Georgiou C . Balloon tamponade in the management of postpartum haemorrhage: a review. BJOG 2009;116:748–57.[doi:10.1111/j.1471-0528.2009.02113.x](http://dx.doi.org/10.1111/j.1471-0528.2009.02113.x) [CrossRef](http://innovations.bmj.com/lookup/external-ref?access_num=10.1111/j.1471-0528.2009.02113.x&link_type=DOI) [PubMed](http://innovations.bmj.com/lookup/external-ref?access_num=19432563&link_type=MED&atom=%2Fbmjinnov%2F6%2F1%2F1.atom) 8. Bakri YN . Uterine tamponade-drain for hemorrhage secondary to placenta previa-accreta. Int J Gynaecol Obstet 1992;37:302–3.[doi:10.1016/0020-7292(92)90336-H](http://dx.doi.org/10.1016/0020-7292(92)90336-H) [PubMed](http://innovations.bmj.com/lookup/external-ref?access_num=1350550&link_type=MED&atom=%2Fbmjinnov%2F6%2F1%2F1.atom) 9. Bakri YN . Balloon device for control of obstetrical bleeding. Eur J Obstet Gynecol Reprod Biol 1999;86:S33–101. S84. 10. Bakri YN , Amri A , Abdul Jabbar F . Tamponade-balloon for obstetrical bleeding. Int J Gynaecol Obstet 2001;74:139–42.[doi:10.1016/S0020-7292(01)00395-2](http://dx.doi.org/10.1016/S0020-7292(01)00395-2) [CrossRef](http://innovations.bmj.com/lookup/external-ref?access_num=10.1016/S0020-7292(01)00395-2&link_type=DOI) [PubMed](http://innovations.bmj.com/lookup/external-ref?access_num=11502292&link_type=MED&atom=%2Fbmjinnov%2F6%2F1%2F1.atom) 11. Alouini S , Bedouet L , Ramos A , et al . [Bakri balloon tamponade for severe post-partum haemorrhage: efficiency and fertility outcomes]. J Gynecol Obstet Biol Reprod 2015;44:171–5.[doi:10.1016/j.jgyn.2014.05.010](http://dx.doi.org/10.1016/j.jgyn.2014.05.010) 12. Akhter S , Begum MR , Kabir Z , et al . Use of a condom to control massive postpartum hemorrhage. MedGenMed 2003;5:38. [PubMed](http://innovations.bmj.com/lookup/external-ref?access_num=14603137&link_type=MED&atom=%2Fbmjinnov%2F6%2F1%2F1.atom) 13. Utah medical products, Inc. Available: [www.utahmed.com](http://www.utahmed.com) [Accessed 28 Feb 2012]. 14. Tindell K , Garfinkel R , Abu-Haydar E , et al . Uterine balloon tamponade for the treatment of postpartum haemorrhage in resource-poor settings: a systematic review. BJOG 2013;120:5–14.[doi:10.1111/j.1471-0528.2012.03454.x](http://dx.doi.org/10.1111/j.1471-0528.2012.03454.x) 15. Belfort M , Dildy G , Garrido J , et al . Intraluminal pressure in a uterine tamponade balloon is Curvilinearly related to the volume of fluid infused. Am J Perinatol 2011;28:659–66.[doi:10.1055/s-0031-1276741](http://dx.doi.org/10.1055/s-0031-1276741) [PubMed](http://innovations.bmj.com/lookup/external-ref?access_num=21500144&link_type=MED&atom=%2Fbmjinnov%2F6%2F1%2F1.atom) 16. Barinov SV , Zhukovsky Ya G , Dolgikh VT , et al . Controlled balloon tamponade in the combined treatment of postpartum hemorrhage after cesarean section. Obstetrics and Gynecology 2016:34–40. 17. Alouini S , Coly S , Mégier P , et al . Multiple square sutures for postpartum hemorrhage: results and hysteroscopic assessment. Am J Obstet Gynecol 2011;205:335.e1–335.e6.[doi:10.1016/j.ajog.2011.05.006](http://dx.doi.org/10.1016/j.ajog.2011.05.006) [PubMed](http://innovations.bmj.com/lookup/external-ref?access_num=21722873&link_type=MED&atom=%2Fbmjinnov%2F6%2F1%2F1.atom) 18. Embrey MP , Hillier K . Therapeutic abortion by intrauterine instillation of prostaglandins. Br Med J 1971;1:588–90.[doi:10.1136/bmj.1.5749.588](http://dx.doi.org/10.1136/bmj.1.5749.588) [Abstract/FREE Full Text](http://innovations.bmj.com/lookup/ijlink/YTozOntzOjQ6InBhdGgiO3M6MTQ6Ii9sb29rdXAvaWpsaW5rIjtzOjU6InF1ZXJ5IjthOjQ6e3M6ODoibGlua1R5cGUiO3M6NDoiQUJTVCI7czoxMToiam91cm5hbENvZGUiO3M6MzoiYm1qIjtzOjU6InJlc2lkIjtzOjEwOiIxLzU3NDkvNTg4IjtzOjQ6ImF0b20iO3M6MjA6Ii9ibWppbm5vdi82LzEvMS5hdG9tIjt9czo4OiJmcmFnbWVudCI7czowOiIiO30=) 19. Kinugasa M , Tamai H , Miyake M , et al . Uterine balloon tamponade in combination with topical administration of tranexamic acid for management of postpartum hemorrhage. Case Rep Obstet Gynecol 2015;2015:195036 [doi:10.1155/2015/195036](http://dx.doi.org/10.1155/2015/195036) 20. Simonazzi G , Bisulli M , Saccone G , et al . Tranexamic acid for preventing postpartum blood loss after cesarean delivery: a systematic review and meta-analysis of randomized controlled trials. Acta Obstet Gynecol Scand 2016;95:28–37.[doi:10.1111/aogs.12798](http://dx.doi.org/10.1111/aogs.12798)